workplace exposure limits

On 1 December, Australia’s Workplace Exposure Standards become Workplace Exposure Limits.

The change from standard to limit is deliberate. These aren’t recommended targets; they’re levels that must not be exceeded.

But the terminology isn’t the only thing changing.

 

Limits for some airborne contaminants are moving, new contaminants are being added, and 33 non-threshold genotoxic carcinogens will no longer have a numeric exposure limit at all.

For manufacturers generating or working around dusts, fumes, gases, vapours and mists, now is the time to work out which of those changes actually affect your workplace.

Workplace Exposure Limits – What’s actually changing?

The new WEL list replaces the existing WES list nationally from 1 December 2026. And there isn’t one simple rule that applies to every contaminant.

Some limits are changing. Some contaminants will have lower exposure limits, while others will have higher ones. Don’t assume a figure you’ve been working to remains the same, check the contaminant against the new WEL list.

New contaminants are being added. Diesel particulate matter and flour dust are among those receiving exposure limits. For manufacturers using diesel-powered plant indoors or in enclosed areas, the introduction of a WEL for diesel particulate matter is particularly relevant.

From 1 December, the WEL for diesel particulate matter will be 0.01 mg/m³, measured as respirable elemental carbon.

33 substances will no longer have a numeric exposure limit. These are non-threshold genotoxic carcinogens (NTGCs), where any level of exposure may increase the risk of cancer.

From 1 December, PCBUs must eliminate the use of these substances where reasonably practicable. If elimination isn’t reasonably practicable, they must substitute them with a safer alternative where possible or minimise the risk so far as is reasonably practicable.

That’s a significantly different approach from simply keeping exposure below a number.

What isn’t changing on 1 December?

There has been some uncertainty around nine chemicals that were subject to further review, including respirable crystalline silica, benzene, formaldehyde and chlorine. For 1 December, their exposure levels aren’t changing. Their existing WES exposure levels will carry across into the new WEL framework while further work continues.

That’s an important distinction if you’ve seen earlier information suggesting new limits for these substances were coming into effect in December.

For now, manufacturers should continue working to the existing exposure levels for those nine chemicals while keeping an eye on future updates from Safe Work Australia.

Start with the substances you actually use or generate

This doesn’t need to begin with rewriting every procedure or retraining the entire workforce.

Start with the workplace.

What airborne contaminants are generated by your processes? What substances are employees working with? Which of those appear on the new WEL list? And, importantly, which limits have changed?

That might include contaminants generated through welding, cutting, grinding, spraying, mixing, cleaning or running diesel-powered equipment.

Once you know what has changed, you can work out whether your existing risk assessments, air monitoring, controls, procedures and training still reflect the current requirements.

Safe Work Australia also released new guidance in July 2026 to help PCBUs prepare, including guidance on managing airborne contaminants, air monitoring and diesel engine emissions.

Then check what else the change touches

For affected contaminants, there are several places worth reviewing.

Risk assessments and controls. If an exposure limit used in an existing assessment is changing, review whether the assessment, monitoring program and controls are still appropriate against the new WEL.

Remember, staying below a WEL isn’t the whole obligation. Airborne contaminant risks must still be eliminated where reasonably practicable or otherwise minimised so far as reasonably practicable.

Safety Data Sheets. Check whether the SDSs for substances you use reflect the new exposure limits, particularly where a limit has changed. If they don’t, contact the manufacturer or supplier for current information.

If your procedures or training quote figures directly from an SDS, check those references too.

Procedures and workplace information. Look for documents that still reference a Workplace Exposure Standard, particularly where the terminology or underlying limit is important to how the task is performed.

Training and induction content. If a module, toolbox talk or induction states a specific exposure number, check it against the new WEL.

And don’t update a number simply for the sake of updating a number. If a changed limit affects how a task should be performed, what controls are required or how workers need to respond, that’s the information people actually need to understand.

What should manufacturers do before 1 December?

A practical starting point:

  1. Pull your chemical and airborne contaminant information and identify what your workplace uses or generates.
  2. Compare relevant contaminants against the new WEL list, prioritising those with changed or newly introduced limits.
  3. Review risk assessments, monitoring and controls where the exposure limit has changed.
  4. Check SDS information and seek updated documentation from manufacturers or suppliers where required.
  5. Review procedures, induction and training content for outdated WES terminology or exposure figures.
  6. Communicate changes to the people affected, rather than automatically retraining everyone.
  7. Build in a review point. Regulations, guidance and exposure limits change. Your workplace information needs a way of keeping up.

The objective isn’t to generate a mountain of new compliance paperwork before December.

It’s to identify what has actually changed for your workplace, and make sure your controls, information and training change with it.

Where MyBrand Digital fits in

Updating workplace training is one part of preparing for the new WEL framework. If your hazardous chemicals, airborne contaminants, WHS or induction content references outdated exposure standards, terminology or procedures, now is a good time to review it.

MyBrand Digital’s library of 100+ brandable eLearning modules can be customised to suit your organisation, while our custom eLearning team can update or develop training around workplace-specific requirements.

That means you don’t necessarily need to rebuild an entire course because one part of your compliance environment has changed.

If you’re reviewing your workplace training ahead of 1 December, talk to the MyBrand Digital team about what needs updating and what doesn’t.

Sources

Safe Work Australia – New Workplace Exposure Limits (WEL) apply 1 December 2026

Safe Work Australia – Workplace Exposure Limits for airborne contaminants

Safe Work Australia – Changes between WES and WEL

Safe Work Australia – Decision Regulation Impact Statement: proposed workplace exposure limits for 9 chemicals

Safe Work Australia – New guidance for managing workplace exposure to airborne contaminants